CMC Non Contact
Menu

CMC Coded Magnetic Non Contact

 

IDEM Safety SwitchesThe IDEM CMC Hygiecode - coded non contact

  • Tested IP69K (high pressure hosing with detergent at 80C and 100psi)
  • Coded magnetic actuation
  • Will operate with most safety relays
  • 20mm Slim wide housing
  • Can be high pressure hosed at high temperature - IP69K
  • Wide 14mm sensing high tolerance to misalignment
  • LED indication
  • 2NC & 1NC Circuits - High Switching Life - no moving parts

The IDEM hygiecode coded non contact CMC switch has three switched which connect in series to either SCR-2 or SCR-3 to give dual channel monitoring with auto start and contactor feedback check. There is an optional auxiliary circuit which provides remote signalling from each switch. This CMC IDEM switch has been designed to work with 105C but can go up to 125C; it has also been designed with a stainless steel mirror polish finish Ra4 housing.

The IDEM CMC is specifically designed for food processing applications with EHEDG guidelines for food splash zone which is suitable for CIP and SIP cleaning. This CMC has been designed to industry standards with a slim 20mm wide hosing which can be fitted in narrow channels, with the M12 versions you have quick connect and 250mm (10”) cable and a switching tolerance up to 14mm.

 

CMC Non Contact Main Features


Standards EN1088 IEC 60947-5-3 EN 60204-1 ISO 13849-1 EN62061 EN 954-1 UL 508
Safety classification and reliability data
Switching reliability 3.3 x 106 operations at 100mA load
EN 954-1 Up to category 4 with safety relay
ISO 13849-1 Up to PLe depending upon system architecture
EN 62061 Up to SIL3 depending upon system architecture
Safety data - Annual usual 8 cycles per hour / 24 hours a day / 365 days
PFHd 2.52 x 10-8
Proof test interval (life) 47 Years
MTTFd 470 Years
Safety Channel 1 NC 24V.dc 0.2A Max. rating
Safety channel 2 NC 24V.dc 0.2A Max. rating
Safety channel 3 NO 24V.dc 0.2A Max. rating
Minimum switched current 10V.dc 1mA
Dielectric withstand 250V.ac
Insulation Resistance 100 Mohms
Recommended setting gap 5mm
Switching distance Sao 10mm close
Target to target Sar 20mm open
Tolerance to misalignment 5mm in any direction from 5mm setting gap
Switching frequency 1.0Hz minimum
Approach speed 200mm/m to 1000mm/s
Body material Stainless steel 316 Mirror polished finish (Ra4)
Temperature Range -25 + 105C
Enclosure Protection IP69K IP67
Shock resistance IEC 68-2-27 11ms 30g
Vibration resistance IEC 68-2-6 10-55 Hz 1mm
Cable type PVC 6 or 8 core 6mm O.D
Mounting bolts 2 x M4 Tightening torque 1.0 Nm
Mounting position Any

For more information about IDEM CMC coded non contact HYGIDECODE Switches, contact More Control on 0345 00 00 400.

Office Address 

21 Drakes Mews
Crownhill Industrial Estate
Milton Keynes
MK8 0ER

Tel: 0345 00 00 400

Email: This email address is being protected from spambots. You need JavaScript enabled to view it.